Coupling Correcting Method And Device Measures
Sep 09, 2019
1, coupling radially looking positive When the coupling is looking positive, the vertical orientation should be adjusted first. The thickness of the front and rear foot gaskets can be calculated by three-point detection data to detect the offset of the two axes. The outer edge diameter of the movable end coupling plus the distance from the outer edge of the coupling to the center of the axial thousand-point tab hole; From the above data, you can know the thickness of the front and rear foot gaskets.
If the motor is higher than the fixed end, the gasket should be reduced, and if the motor is lower than the fixed end, the gasket should be added. After the vertical direction adjustment, each point detection data has changed, should be re-zeroed at 1 point, re-measured 2, 3 points of data.
After adjustment, simply check and whether within the allowable error range.
2, coupling principle to find positive The projection of the motor movable end face circle on the fixed end face is considered as a positive circle, because the distance between the center of the movable end and the fixed end face is unchanged. If you want to meet at the same time, the movable end axis and the fixed end axis are on a line, just the ideal positive state. When the actual timing is found, the permissible error is set first, and the error generated when the timing is within the allowable error range, the correction ends.
In many cases, the pump's lower detection point can not be detected, looking for positive work will not be able to carry out.
3, three-point tabtoch to find the correct step
(1) Fixed the magnetic fixed seat, measuring rod and thousand meter table on the fixed end and movable end coupling respectively;
(2) turn the shaft to 1 point position, clear the two thousandth table,
(3) turn the shaft to the 2 point position and read out the data;
(4) turn the shaft to the 3 point position, read the data,
(5) calculate
(6) the motor front, the Rear foot bolt loosened, in the motor front, rear foot separately pad, thick gasket, move the motor, try to make the two couplings close, and then the motor front and rear foot bolts tightened, in 1 point will be two thousand meters of the table zero, in 2, 3 points to read out the data, with the set of allowed error value comparison, if not reached the accuracy requirements, repeat the above steps 2-6;
Step 6 is satisfied, the motor front and rear foot bolts slightly loosened, the thousand-point table will be kept at the 3-point position, with a copper rod to hit the moving end of the front and rear feet, and the center of the movable end, horizontal direction to find positive, until, in the allowable error range;
4, coupling axial to find positive Horizontal direction to find positive does not need to calculate the moving end of the front and rear foot volume, at 1 point will be axial and radial thousand meters zero, read 3 points axial and radial thousand meter reading, with copper rod hit the movable end for axial adjustment. First observe the axial meter reading, tap the front and back feet of the movable end with a copper rod, and adjust the axial reading of the 3-point bit to half the original. Then look at the radial thousand meter reading, hit the center of the movable end with a copper rod, and adjust the radial reading of the 3-point bit to half the original. This needs to be adjusted over and over again.
The result of the adjustment should be made and within the allowable error range. Membrane coupling device measures: before the diaphragm coupling device, should clean the two shaft end faces, reflect on the common conditions such as end-face key notches; Between films can be coated with solid smooth agents such as disulfide or on the appearance of the diaphragm to reduce the coating disposal, high-speed diaphragm coupling; - Appropriate safety precautions must be accepted at sites that can cause personal and equipment disturbances due to the operation of diaphragm couplings. Pay attention to the problem of coupling device, correct handling to ensure the completion of installation. Regular observation, inspection, maintenance work, practical installation.